Measurement range
| 0% to 100% relative humidity
|
Accuracy
| 5% from 35% to 90% RH, 5% elsewhere
|
Maximum response time
| 5 min from 95% to 35%, 3 min for 10% step change
|
Immersion in water
| Survives 60 min immersion with no effect
|
Filter
| 20 micron porous bronze - replaceable
|
Indicators
| 1 power LED (green), 1 replace filter LED (red)
|
Current loop output
| 4.0 to 20.0 mA
|
Maintenance output
| Logic level 0-5V
|
Resistance to Ammonia
| 100 ppm for 24 hrs, 20 ppm long term with no effect
|
Resistance to chemical vapours
| Yes - consult factory for details
|
Operating temperature
| +5 to +50 Celsius
|
Supply voltage
| +10 to +14 VDC
|
Current consumption
| 100 mA max
|
Connection
| 6 pole PCB screw terminal
|
Mounting
| Two mounting ears, 4.6" apart
|
Size
| 4.0"H by 4.0"W by 2.4"D
|
Weight
| 11.9 oz
|
Warranty
| 1 year |