| Measurement range
| 0% to 100% relative humidity
|
| Accuracy
| 5% from 35% to 90% RH, 5% elsewhere
|
| Maximum response time
| 5 min from 95% to 35%, 3 min for 10% step change
|
| Immersion in water
| Survives 60 min immersion with no effect
|
| Filter
| 20 micron porous bronze - replaceable
|
| Indicators
| 1 power LED (green), 1 replace filter LED (red)
|
| Current loop output
| 4.0 to 20.0 mA
|
| Maintenance output
| Logic level 0-5V
|
| Resistance to Ammonia
| 100 ppm for 24 hrs, 20 ppm long term with no effect
|
| Resistance to chemical vapours
| Yes - consult factory for details
|
| Operating temperature
| +5 to +50 Celsius
|
| Supply voltage
| +10 to +14 VDC
|
| Current consumption
| 100 mA max
|
| Connection
| 6 pole PCB screw terminal
|
| Mounting
| Two mounting ears, 4.6" apart
|
| Size
| 4.0"H by 4.0"W by 2.4"D
|
| Weight
| 11.9 oz
|
| Warranty
| 1 year |